Keep the motor’s specified nominal capacitance. A higher AC voltage rating is only a replacement option within the equipment maker’s approved specification and with the correct duty, frequency and fit. Capacitance and voltage are separate selection decisions.
More µF changes the motor circuit
Capacitance affects current and phase displacement in the auxiliary winding. A larger value can change torque, vibration and heating. For a motor specified at 20 µF, choosing 25 µF to improve starting is an electrical change, not an ordinary like-for-like replacement. Use the motor’s approved value. Oriental Motor: replacement capacitor guidance
Tolerance describes variation around a nominal value. A 20 µF ±5% label gives 19–21 µF; ±10% gives 18–22 µF. A wider tolerance is not permission to order an unrelated nominal value. For dual-run capacitors, preserve the specified value and tolerance of each section.

20 µF · 450 VAC · ±5%
On this CBB65 label, 20 µF ±5% gives the capacitance and tolerance. The voltage rating is 450 VAC.
Capacitor voltage is not the mains supply voltage
VAC is the capacitor’s rated AC voltage. The voltage across a capacitor in the motor circuit can differ from the line voltage. A motor supplied at a lower voltage can therefore still specify a 450 VAC run capacitor. Select from the motor requirement rather than reducing the capacitor rating to the supply value.
Questions about 370 versus 440 VAC, or 440 versus 450 VAC, need the full replacement specification. A higher printed voltage does not resolve differences in construction, operation class, temperature or duty. Never infer starting-duty compatibility from the voltage alone.
The electrical match still needs an installed fit
A run capacitor can use a round or oval case, wire leads or quick-connect terminals. The replacement must fit the bracket and provide the right connection geometry with the connector installed. Temperature category and any required design-life class stay tied to the selected model and its rated conditions.
For an approved substitution, retain the original equipment reference beside the new model datasheet and drawing. That creates a usable cross-reference for future orders. A list containing only µF and VAC loses the connection, mounting and operating limits that made the replacement suitable.
Compare a proposed replacement
Send the original motor requirement and the proposed capacitor data so the differences can be identified in one model record.