CD60
motor start capacitors
Electrolytic start capacitors for switched single-phase AC motor circuits.
- Duty
- StartFor a switched motor-start circuit
- Capacitance range
- 20–1500 µF
- Rated voltage
- 110–330 VAC
The circuit must disconnect CD60 after startup. Follow the rated starting time and interval between starts.
Request a CD60 quoteTechnical specifications
CD60 is an aluminium electrolytic capacitor used during motor startup. The starting circuit must disconnect it once the motor is running. Choose it by its electrical ratings and starting-duty limits, including the permitted starting time and interval between starts.
Electrical
- Function
- Start duty
- Capacitance range
- 20–1500 µF
- Rated voltage
- 110–330 VAC
- Series tolerance
- ±10% (K), ±20% (M)
- Frequency
- 50/60 Hz
- Series temperature range
- −20 to +65 °C
Case & connection
- Case format
- Electrolytic start-capacitor case
- Series case-size range
- Approximately 34 × 60 to 63 × 110 mm; use the model drawing for exact dimensions.
- Construction
- Aluminium electrolytic start-capacitor construction.
- Connection
- Blade terminals or wire leads, depending on the model.
Sample configurations & fit
| Photo reference | Capacitance | Rated AC voltage | Tolerance / frequency | Visible connection | Inquiry |
|---|---|---|---|---|---|
| P038Start-capacitor sample | 500 µF | 300 VAC | ±5% 50/60 Hz | Blade terminals | Model details |

Motor-start sample
- Visible markings
- 500 µF ±5% · 300 VAC
- Connection / fixing
- Blade terminals visible
- Include body dimensions, terminal or lead connections and installed clearance on the drawing.

Applications
Water pumps
Pump motors with a separately switched start-capacitor circuit.
Air conditioners / HVAC
Compressor motors with a separately switched start-capacitor circuit.
Other single-phase AC motor starting
Switched start circuits with specified on-time and repeat-start limits.
CD60 datasheets & drawings
Request the datasheet and drawing for your selected rating and connection. Include the destination when requesting test reports or certificates.
- Current datasheet
- Exact model number and revision, µF, VAC, tolerance, frequency and operating temperature.
- Dimensioned drawing & revision
- Body dimensions, terminal configuration and installed clearance. Starting circuit and switching arrangement.
- Duty information
- Maximum starting time, minimum rest interval, repeat-start limits and tolerance for the selected model.
- Test reports & certificates
- Model and destination coverage, issuer, certificate or report number, and validity.
Ordering & samples
- Standard MOQ
- 5,000 pieces in total across mixed models. Confirm the quantity for each model in the quotation.
- Test samples
- Free test samples are available for eligible models. Confirm the sample quantity, any customisation charges, freight and preparation date before dispatch.
- Production lead time
- Lead time is quoted for your model, quantity, label and packing. Sample preparation and transport have separate dates; the quotation identifies which approval or payment event starts the production period.
- Label & packing
- Send artwork and any connection or packing requirements with the model specification.
- Warranty
- All models carry a warranty of at least three years. The written quotation or contract specifies the start date, coverage, exclusions and claim procedure.
- Payment methods
- We accept T/T bank transfers and L/C letters of credit. Agree the currency, payment schedule and any letter-of-credit conditions in the written quotation or contract.
Request a CD60 quote
Send the capacitor label or model number, quantity and delivery destination.
- Motor model and capacitor label or specification
- Drawing or measurements for the case, mounting and connections
- Starting circuit, switching arrangement and duty limits
- Quantity by rating and destination