Skip to content

Capacitors for fans and blowers

CBB61 rectangular and CBB60 cylindrical run capacitors for fan and blower motors, with the connections and installation space each format needs.

Centrifugal ventilation blower with an enclosed electric motor.

Motor circuit and capacitor requirements

  1. Motor rating

    Find run duty, µF and VAC in the motor specification and original capacitor label.

  2. Rectangular case

    For a CBB61, compare the case size, mounting tabs and blade or wire connections with the drawing.

  3. Cylindrical case

    For a CBB60, allow room for the body and fixing as well as the wire leads.

Compare capacitor series

Run-capacitor formats for fan motors
FieldCBB61Run duty · Fan runCBB60Run duty · Motor run
DutyRectangular run format for fan and blower motors.Cylindrical run format for the specified motor circuit.
Case / connectionInsulated rectangular case · Lead wires / blade terminalsInsulated cylindrical case · Lead wires / quick-connect terminals
Electrical ratingSeries voltage range: 250–450 VAC. Capacitance ranges are on the series page.Series voltage range: 110–450 VAC. Capacitance ranges are on the series page.
Series case-size rangeL 37–73 × W 12–40 × H 24–53 mm (series range).Diameter 30–60 mm; height 60–125 mm (series range).
Installation requirementMounting tabs, lead exit or blade pattern, and the fitted connector.Cylindrical body, fixing and space for routed leads.
Product view
CBB61 rectangular capacitor with two blade terminals.
CBB60 cylindrical capacitor with insulated wire leads.
Full series detailsView CBB61View CBB60

CBB61

CBB61 rectangular capacitor with two blade terminals.
Duty
Rectangular run format for fan and blower motors.
Case / connection
Insulated rectangular case · Lead wires / blade terminals
Electrical rating
Series voltage range: 250–450 VAC. Capacitance ranges are on the series page.
Series case-size range
L 37–73 × W 12–40 × H 24–53 mm (series range).
Installation requirement
Mounting tabs, lead exit or blade pattern, and the fitted connector.
View CBB61 details

CBB60

CBB60 cylindrical capacitor with insulated wire leads.
Duty
Cylindrical run format for the specified motor circuit.
Case / connection
Insulated cylindrical case · Lead wires / quick-connect terminals
Electrical rating
Series voltage range: 110–450 VAC. Capacitance ranges are on the series page.
Series case-size range
Diameter 30–60 mm; height 60–125 mm (series range).
Installation requirement
Cylindrical body, fixing and space for routed leads.
View CBB60 details

The model datasheet provides the applicable temperature, tolerance and dimensional limits.

Mounting and connection requirements

Two CBB61 capacitor samples with red wire leads and mounting tabs.
CBB61 samples · lead exit and mounting tabs
  • Case and mounting tabs

    Record L / W / H for a rectangular case or D / H for a cylindrical body. Include fixing positions and the available mounting space.

  • Wire leads

    Specify exit direction, wire count, length and connector on the wiring diagram.

  • Blade terminals

    For terminal-type parts, specify the blade pattern and spacing on the model drawing.

Ask about capacitors for fans and blowers

Send the motor details and the quantity you need.

  • Fan and motor model, with the original capacitor label.
  • Drawing or measurements showing the case, mounting and connections.
  • Quantity by rating and destination.
Quotation checklist