CBB60 is a cylindrical film motor run capacitor. Choose its capacitance from the motor specification, then match the rated AC voltage, operating conditions and physical installation. A CBB60 designation identifies the family; it does not identify a complete replacement part.
Where does a CBB60 belong?
In a capacitor-run single-phase motor, the capacitor remains connected to the auxiliary winding during operation. CBB60 applications include water pumps and selected washing-machine, blower and smoke-exhaust motors designed for this arrangement. An inverter-driven motor or a motor with a different starting circuit needs its own specified component.
The HAN XING catalogue describes metallized polypropylene film in an insulated plastic case. Its published family range is 2–100 µF and 110–450 VAC. Those endpoints describe the catalogue range; the quoted model determines the available combination of capacitance, voltage and case.
25 µF and 35 µF are different motor requirements
The supplied wired HAN XING sample is marked 35 µF ±5%, 450 VAC and 50/60 Hz. The horizontal sample in photograph P003 is 25 µF, also at 450 VAC. A motor specified for 25 µF still requires that value even if the 35 µF case fits its bracket. Increasing capacitance changes the auxiliary-winding current and motor behavior.
For a replacement, keep the specified nominal µF. A higher AC voltage rating is an option only within the motor maker’s approved replacement specification, with the same duty and suitable dimensions. A 450 VAC label describes the capacitor rating, not a requirement to run the motor from a 450 V supply. Oriental Motor: replacement capacitor guidance
35 µF wired CBB60 sample
The complete original label and both insulated leads are visible.
Temperature category and installed fit
The 35 µF sample carries 40/70/21. The catalogue lists −40 to +85 °C for the series, while the selected model defines its own temperature category. Neither source establishes a universal CBB60 life class. Any Class B or other life claim needs its rated voltage, temperature and supporting model document.
Wire leads suit an assembly with a routed harness. Quick-connect blades suit a defined mating connector. A base stud changes the mounting envelope, while a twin-core cable needs its exit direction and finished length specified. The body diameter alone cannot describe these installations.
Find the CBB60 for your motor